Ohm's law calculator

Ohm's law is V = I × R, and power is P = V × I. Any two of voltage, current, resistance and power give the other two: a 1,500 W heater on 120 V draws 12.5 A, and its element is 9.6 Ω.

Type any two values; the calculator fills in the other two and shows the formula it used. For DC and purely resistive loads. It runs in your browser; nothing you type is saved or sent.

Example values, not benchmarks. Replace them with your own.

Enter any two

Entered.

Calculated. Type here to enter it instead.

Calculated. Type here to enter it instead.

Entered.

Current
12.5 A
Resistance
9.6 Ω

The formula used, with your numbers

I = P ÷ V = 1,500 W ÷ 120 V = 12.5 A
R = V² ÷ P = (120 V)² ÷ 1,500 W = 9.6 Ω

For DC and purely resistive loads only: with a motor, a ballast or any other inductive or capacitive load, power is not simply volts × amps.

What are the Ohm's law formulas?

Twelve formulas, three for each quantity, all from V = I × R and P = V × I. They are the Ohm's law wheel written as a table: pick the row for what you want and the formula that uses the two values you have.

The twelve Ohm's law and power formulas
To find Use any one
Voltage (V) V = I × RV = P ÷ IV = √(P × R)
Current (I) I = V ÷ RI = P ÷ VI = √(P ÷ R)
Resistance (R) R = V ÷ IR = V² ÷ PR = P ÷ I²
Power (P) P = V × IP = I² × RP = V² ÷ R

Does Ohm's law work for AC circuits?

Only for purely resistive loads, such as heating elements and incandescent lamps, where the current is in step with the voltage. A motor, transformer, ballast or electronic driver has reactance too, so its current isn't volts ÷ ohms and its real power is less than volts × amps by its power factor. This calculator doesn't model power factor or three-phase power.

Related tools

  • Wire ampacity calculator: Get a conductor's allowable ampacity from NEC Table 310.16, derated for ambient and conductor count and capped at the 75 °C or 60 °C termination rating.
  • Wire size calculator: Find the smallest wire for a load from NEC Table 310.16, with the 125% continuous-load factor, 240.4(D) breaker limits and an optional voltage-drop limit.
  • Voltage drop calculator: Get a run's voltage drop in volts and percent from the NEC Chapter 9 Table 8 resistance, single- or three-phase, or the longest run that stays within a target drop.
  • Metric voltage drop calculator: Voltage drop in metres: type the cable's mV/A/m from its datasheet, the current, the length and the voltage for the drop in volts and percent, and a pass or fail against your own limit.
  • Ground wire size calculator: Size the equipment grounding conductor from NEC Table 250.122, and upsize it in proportion when the phase conductors were upsized for voltage drop (250.122(B)).
  • Neutral conductor size calculator: Size a feeder or service neutral from the NEC 220.61 unbalanced load, with the 70% reduction over 200 A, and the Table 250.122 or 250.102(C)(1) minimum.
  • Motor circuit calculator: wire, breaker and ground size: Size a single motor's branch circuit from NEC Article 430: full-load current, the conductor at 125%, the largest breaker or fuse, the ground wire and the overload.
  • Transformer amps calculator: Get a transformer's primary and secondary full-load amps from its kVA, phase and voltages, with a table for the standard kVA ratings.
  • Conduit support spacing calculator: Get the NEC maximum distance between conduit supports and from a box for EMT, IMC, RMC, PVC, RTRC, ENT, FMC, LFMC and LFNC, and the minimum strap count for a run.
  • Conduit fill and size calculator: What size conduit do you need? Mix wire types and sizes, grounds included, and get the smallest conduit that fits plus the fill % in every trade size, from NEC Chapter 9.
  • Metric conduit fill calculator: Conduit fill in millimetres: type the conduit's internal diameter and each cable's overall diameter for the fill %, a pass or fail against your own limit and the largest cable that still fits.
  • Fire alarm battery calculator: Size a fire alarm panel's standby battery in amp-hours from your devices' standby and alarm currents, the NFPA 72 standby and alarm times and a safety margin.
  • Low-voltage cable footage calculator: Turn device counts into cable footage and 1,000 ft boxes: cables per device, average run and service loop per device type, plus waste, with a 295 ft check.
  • Sleeve fill calculator: How many cables fit in a sleeve through a wall: the fill % against your firestop listing's max fill, the NEC 60% nipple and Table 1 figures for reference, and how many more cables fit.
  • All free tools for electrical estimators

Questions

Frequently asked

Can't find an answer? Email contact@takeonbid.com — we read every one.

  • What is Ohm's law?

    Ohm's law says the voltage across a resistance equals the current through it times the resistance: V = I × R. With the power formula P = V × I, any two of voltage, current, resistance and power give the other two.

  • How many amps does a heater draw?

    Divide its watts by the voltage: I = P ÷ V. A 1,500 W heater on 120 V draws 1,500 W ÷ 120 V = 12.5 A. Its element's resistance is V² ÷ P = 9.6 Ω.

  • Does Ohm's law work for AC?

    Yes, for purely resistive loads such as heating elements and incandescent lamps. Motors, transformers, ballasts and electronic loads have reactance, so their current isn't simply volts ÷ ohms and their power isn't simply volts × amps: the power factor comes in. This calculator is for DC and resistive loads only.

  • What units does the calculator use?

    Volts (V), amperes (A), ohms (Ω) and watts (W). Enter kilowatts as watts (1.5 kW = 1500 W) and milliamps as amps (250 mA = 0.25 A). Answers are rounded to four significant figures.

  • Does this calculator save or send what I type?

    No. The calculator runs entirely in your browser. Nothing you enter is saved or sent anywhere, and no account is needed.

From the drawings to the bid

Count it, run it, price it.

TakeOn measures your devices and runs off the plans and turns them into a priced electrical bid. No credit card needed.